>> click here to view and print Brochure
Cityview Corporate Center
160 Chubb Avenue, Lyndhurst, NJ
Type: Class "A" Office Building
Building Size: 135,365 Rentable Square Feet
Floor Size:
3 Floors of 46,100 Rentable Square Feet
Year Built: Originally 1977, Completely Rebuilt 2001
Ownership: Kwartler Associates, Inc.
Parking: 547 spaces (includes 10 handicapped spaces)
Building Exterior: Anodized Aluminum Panels and Reflective Glass Curtain Wall
Roof: A new, fully warranted mechanically fastened EPDM roof
Access Control System: Computer monitored card access system
Structural: The building is constructed over a 3-Story structural steel frame. The structural bays are 25-feet x 30-feet. The floor construction is 3-1/2" metal deck
Live Floor Load: 100 lb. PSF- second and third floors
Ceiling Heights/Mullion Spacing: 9' Finished Ceiling Heights; 5' Mullion Spacing
Elevator: Two (2) Passenger with 2,500 lb. capacity One (1) Freight wit 3,500 lb. capacity
Power/Telecommunications: The building is serviced by 277/480 volt, 3 Phase, 4 wire, 2,500 amp service with a pad mounted PSE&G transformer

The service is capable of satisfying the following building load requirements:

· Building HVAC systems
· Building Common Area power & lighting
· Building site lighting
· Tenant area general power and lighting at 6.5
watts/square foot (total connected load)

The building is provided with a utility electric meter. The tenant power is monitored either by sub-meter or survey for all tenant power, lighting loads and special cooling loads
HVAC: The building HVAC will include six (6) new package cooling systems to allow maximum flexibility and economical after-hours service.

The air will be distributed through a variable air volume system located, as required, throughout the tenant spaces.

The heating plant consists of gas-fired boilers, distributing hot water to the perimeter VAV Terminals and supplemental cabinet heaters at the entranceways and within the third floor ceiling plenum.
Automatic Fire Suppression System: The building common areas are fully Sprinklered and tenant space will be as required in accordance with all codes, including NFPA
Fire Protection: A fire alarm system for the buildings common areas is installed in accordance with all current applicable building codes including NFPA and ADA
Emergency Lighting & Exit Lights: Emergency lighting and exit lights for the Building common areas are installed in accordance with all current applicable building codes including NFPA and ADA
Energy Generators/UPS: An emergency generator provides back-up power for building life safety systems, building lighting for emergency egress and tenant emergency lighting.

A dedicated tenant distribution switchboard capable of providing for a total connected load of 6.5 watts/useable square foot for tenants' lighting and power is provided in the 1st floor main electric room.
Highway Access: · 5 Miles to the Lincoln Tunnel and Garden State Parkway
· 1.25 miles to the New Jersey Turnpike
· .8 Miles to Routes 3 and 17
· 13 Miles to the Holland Tunnel
Public Transportation: · NJ Transit Bus #192 to NY/PA
· NJ Transit Rail #76 Lyndhurst Station to Hoboken
· Shuttle Service to building from Lyndhurst Station
Airports: · 13.2 miles to Newark International Airport
· 4.9 miles to Teterboro Airport
Fiber Optic Capability: Fiber Optic service is available in the building. Multiple conduits, from several providers, are available in the street.
Café: Cityview Cafe provides gourmet catering services and after hours vending.
Area Amenities: Close proximity to child care, health club And several restaurants. The Marriot Courtyard, Renaissance Meadowlands Hotel, & Sheraton Hotels are minutes away and offer shuttle-service to the building.

building specs | site plan | floor plans

property details | location | amenities | photos | directions | contact us | home